Sign In | Join Free | My ecer.jp
China HK FY-MED TRADING CO., LIMITED logo
HK FY-MED TRADING CO., LIMITED
Hong Kong FY-Medical Trading Co., Ltd., serving in the field of medical endoscope for 10 years, focusing on the research and development, production, sales, maintenance, renovation and other business
Verified Supplier

2 Years

Home > Endoscopy Processor >

2215 Laparo Pump Instrument Carts Pump Power In Good Condition

HK FY-MED TRADING CO., LIMITED
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

2215 Laparo Pump Instrument Carts Pump Power In Good Condition

  • 1
  • 2
  • 3

Model Number : 2215

Contact Now

2215 Laparo Pump Instrument Carts Pump Power In Good Condition

1. Function Introduction:


LAPARO PUMP 2215 -

Effective irrigation and suction in

within the framework of laparoscopic, minimally invasive

surgery.

- Easy handling due to simplicity of the instrument

- Optimal suction and lavage performance

- Compatibility with suction-

Compatible with suction and lavage instruments with integrated valves,

Particularly compatible with the modular suction/ irrigation arm of the R. Wolf

- High degree of safety through intelligent pressure control

- Simple fastening to flushing columns or

easy mounting on flushing stands or instrument carts

2. Parameters Of 2215 Laparo Pump

​​

  • Power supply connection 220-240 V AC, 50/60 Hz

  • Power consumption 55 VA

  • Dimensions (W x H x D) 143 x 317 x 170 mm

  • Maximum flushing capacity: 1.8 l/min, suction: 1.8 l/min

  • Maximum flushing pressure: 400 mmHg (±50 mmHg)

  • Vacuum, minimum -60 kPa (-10 kPa)

  • Weight approx. 6 kg


Recommendations for Endoscopic Maintenance and Care


  • Do not place the endoscope together with other instruments and avoid touching other parts with the insertion part.

  • Wait until the endoscope angle returns to the 0-degree state before pulling out.

  • Since the insertion part is long, please be careful when cleaning and storing it, and be sure to confirm that it is not stuck beforehand.

  • When sterilizing EVIS endoscopes with ethylene oxide, remove the waterproof cap; when sterilizing other endoscopes with ethylene oxide, put on the ETO cap.

  • Wait until the endoscope angle returns to the 0-degree state, then pull out from the trocar needle and trocar.

  • When adjusting the angle of the insertion part, the angle should not be smaller than the range indicated in the instruction manual.

  • Please keep the sheath as straight as possible during operation.

  • Hold the insert gently and handle it carefully when taking it out.



2215 Laparo Pump Instrument Carts Pump Power In Good Condition


2215 Laparo Pump Instrument Carts Pump Power In Good Condition









Product Tags:

Power Laparo Pump Instrument Carts

      

Good Condition Laparo Pump Instrument Carts

      

2215 Laparo Pump Instrument Carts

      
Quality 2215 Laparo Pump Instrument Carts Pump Power In Good Condition wholesale

2215 Laparo Pump Instrument Carts Pump Power In Good Condition Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: HK FY-MED TRADING CO., LIMITED
*Subject:
*Message:
Characters Remaining: (0/3000)