CV-240 Video Processor and CLV-240 Xenon Endoscopy Light Source

1. Function Introduction:

The Olympus CV-240 Video Processor is compatible with standard and big chip endoscopes. The CV-240 allows the user to enhance, freeze, and adjust color settings to provide clear and accurate images from inside the body.

Compatible with the full range of endoscopes from EVIS 100, 130 and 140 series endoscopes

Wide screen image functionality with used in conjunction with Q series endoscopes such as GIF-Q140 and CF-Q140L

Pre-set scope switch functions. Endoscopist has a choice from up to 20 pre-set endoscope switch functions

Pre-program patient data. Up to 40 files of patient data can be pre-entered into memory to expedite procedure turn around.

Recommendations for Endoscopic Maintenance and Care

CV-240 Video Processor And CLV-240 Xenon Endoscopy Light Source

  • Do not place the endoscope together with other instruments and avoid touching other parts with the insertion part.

  • Wait until the endoscope angle returns to the 0-degree state before pulling out.

  • Since the insertion part is long, please be careful when cleaning and storing it, and be sure to confirm that it is not stuck beforehand.

  • When sterilizing EVIS endoscopes with ethylene oxide, remove the waterproof cap; when sterilizing other endoscopes with ethylene oxide, put on the ETO cap.

  • Wait until the endoscope angle returns to the 0-degree state, then pull out from the trocar needle and trocar.

  • When adjusting the angle of the insertion part, the angle should not be smaller than the range indicated in the instruction manual.

  • Please keep the sheath as straight as possible during operation.

  • Hold the insert gently and handle it carefully when taking it out.


Product Tags:

CV-240 Video Processor

      

CLV-240 Xenon Endoscopy Light Source

      

Xenon Endoscopy Light Source

      
Quality CV-240 Video Processor And CLV-240 Xenon Endoscopy Light Source wholesale

CV-240 Video Processor And CLV-240 Xenon Endoscopy Light Source Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: HK FY-MED TRADING CO., LIMITED
*Subject:
*Message:
Characters Remaining: (0/3000)